Micro 1200s current leakage tester

DC leakage measurement,small DC current
Zinc manganese dry battery 6F22 9V, lasting time 30 hours
Clamp CT, non-contact measurement
Detected wires are in the jaw center position

Share to:

Micro-1200s Auto clamp leakage current tester is also called the auto leakage current , auto dark current clamp meter, auto charging current tester.It was designed manufacturing for measuring automobile dark current, leakage current.

                          MICRO-1200Sleakagetester

Function of leakage current tester

Using the latest CT and digital integration technology, non-contact measurement,No need to disconnect the line
Fast, safe and reliable,small size, high precision, anti-interference ability, automatic shift
It can be used for detecting the current leakage rapidly, such as harness breakage leakage, electrical escape, line grounding and other faults, measuring motor starting current, generator charging current and so on.
Widely used in vehicle maintenance, automobile factory inspection, auto parts production testing, telecommunications room current detection, power maintenance, weather, oil field testing.

 

leak tester Specification

Function DC leakage measurement,small DC current
Power Zinc manganese dry battery 6F22 9V, lasting time 30 hours
Measuring way Clamp CT, non-contact measurement
Jaw size 16mm×18mm
Measurement range 0mA~60.0A AC/DC
Resolution 1mA AC/DC 
Accuracy ±2%rdg±5dgt(23℃±5℃,below75%rh)
Display mode 4-digit display
Meter Diamention 215mm×61mm×32mm
LCD Diamention 35mm×21.5mm display diamention 32mm×15mm
Sampling rate 2 times/second
Frequency response AC 45Hz~400Hz
Polarity indication DC current detection automatically identify and display –
Conductor position Detected wires are in the jaw center position
Shift Automatic switching
Line voltage Below AC 600v
Communication parameters Baud rate 9600, data bit 8, stop bit 1, parity bit NONE
Data storage 99 group, flashing  FULL means the memory is full
Data retention DH
Overflow display OL A
Automatic shut-down 5 minutes after the boot, the instrument automatically shut down to reduce battery consumption
Meter weight 220g
Working Current Max 20mA
Working temperature and humidity -10℃~50 ℃;below80%rh
Limit temperature error -10℃~0℃ and 40℃~50℃
Storage temperature and humidity -10℃~60℃;below 70%rh
Dielectric strength AC 3700V/rms
safety regulations IEC1010-1、IEC1010-2-032、Pollution level 2、CAT Ⅲ(600V)